Pipe support spans — MSS-SP-69 / B31.3

Recommended span between supports

Pick NPS + service + material + duty modifier; get the maximum recommended span between supports per MSS-SP-69 with B31.3 Table 321.1 cross-check. Plus a sanity-check on a user-specified span.

Inputs

Reduces base span for vibrating, slug-flow, insulated, or cryogenic service
m
Optional — leave blank to just see the recommendation
baseline (MSS-SP-69) · normal water/process service

Results

Base span (MSS-SP-69)5.2m
× material factor1.00
× service factor1.00
Recommended max span5.2m
Allowable max sag (~L/360)14.4mm
MSS-SP-69 reference table (current modifiers applied)
NPSOD mmwater (m)vapor (m)your conf. (m)
133.42.12.52.1
260.33.03.63.0
388.93.74.43.7
4114.34.35.24.3
6168.35.26.25.2
8219.15.87.05.8
10273.16.47.76.4
12323.97.08.47.0
16406.48.29.88.2
20508.09.411.39.4
24609.610.412.510.4
1-1/248.32.73.22.7
MSS-SP-58 covers hanger / support component design; SP-69 gives recommended spacing. These spans assume single-supported flexible pipe; rigid pipe (heavy-wall thick-flange) can use longer spans. For full B31.3 §319 flexibility analysis with modal frequencies see /console/transport/vibration.